{"product_id":"simtronics-gas-detector-gd10p-p0017dg0xh00-1","title":"Simtronics Gas Detector GD10P P0017DG0XH00","description":"\u003cp data-start=\"97\" data-end=\"636\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"101\" data-end=\"121\"\u003eSimtronics GD10P\u003c\/strong\u003e is a fixed-point infrared gas detector designed for continuous monitoring of combustible hydrocarbon gases in hazardous industrial environments. Using advanced dual-wavelength infrared sensing technology, the GD10P provides highly reliable gas detection without poisoning, sensor drift, or routine recalibration requirements. The detector is specifically designed for demanding oil \u0026amp; gas, petrochemical, offshore, and industrial process safety applications where fast and dependable gas leak detection is critical.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"638\" data-end=\"654\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"655\" data-end=\"1024\"\u003e\n\u003cli data-section-id=\"sriz57\" data-start=\"655\" data-end=\"696\"\u003e\nFixed infrared hydrocarbon gas detector\n\u003c\/li\u003e\n\u003cli data-section-id=\"uq61db\" data-start=\"697\" data-end=\"736\"\u003e\nContinuous combustible gas monitoring\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nsx3g\" data-start=\"737\" data-end=\"782\"\u003e\nDual-wavelength infrared sensing technology\n\u003c\/li\u003e\n\u003cli data-section-id=\"12t4dt6\" data-start=\"783\" data-end=\"821\"\u003e\nImmune to catalytic sensor poisoning\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o4sn0h\" data-start=\"822\" data-end=\"863\"\u003e\nNo routine field recalibration required\n\u003c\/li\u003e\n\u003cli data-section-id=\"eagogv\" data-start=\"864\" data-end=\"899\"\u003e\nContinuous automatic self-testing\n\u003c\/li\u003e\n\u003cli data-section-id=\"1lynsyd\" data-start=\"900\" data-end=\"928\"\u003e\nFast response to gas leaks\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ld0oz\" data-start=\"929\" data-end=\"973\"\u003e\nSuitable for harsh industrial environments\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dwhd8z\" data-start=\"974\" data-end=\"998\"\u003e\nLow maintenance design\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cylqmx\" data-start=\"999\" data-end=\"1024\"\u003e\nHazardous area approved\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1026\" data-end=\"1044\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1045\" data-end=\"1696\"\u003e\n\u003cli data-section-id=\"3etgp8\" data-start=\"1045\" data-end=\"1071\"\u003e\nManufacturer: Simtronics\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gyrgsv\" data-start=\"1072\" data-end=\"1086\"\u003e\nModel: GD10P\n\u003c\/li\u003e\n\u003cli data-section-id=\"auolox\" data-start=\"1087\" data-end=\"1122\"\u003e\nPart Number: GD10-P00-17DG-0XH-00\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hks7ow\" data-start=\"1123\" data-end=\"1159\"\u003e\nDetection Principle: Infrared (IR)\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qitjj1\" data-start=\"1160\" data-end=\"1234\"\u003e\nGas Type:\n\u003cul data-start=\"1174\" data-end=\"1234\"\u003e\n\u003cli data-section-id=\"5zydns\" data-start=\"1174\" data-end=\"1203\"\u003e\nMethane (CH₄) configuration\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fr1t62\" data-start=\"1206\" data-end=\"1234\"\u003e\nHydrocarbon gas monitoring\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fi58l\" data-start=\"1235\" data-end=\"1268\"\u003e\nMeasuring Range:\n\u003cul data-start=\"1256\" data-end=\"1268\"\u003e\n\u003cli data-section-id=\"1g7ppq2\" data-start=\"1256\" data-end=\"1268\"\u003e\n0–100% LEL\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"21rkz9\" data-start=\"1269\" data-end=\"1320\"\u003e\nOutput Signal:\n\u003cul data-start=\"1288\" data-end=\"1320\"\u003e\n\u003cli data-section-id=\"1sapu81\" data-start=\"1288\" data-end=\"1297\"\u003e\n4–20 mA\n\u003c\/li\u003e\n\u003cli data-section-id=\"1kndq93\" data-start=\"1300\" data-end=\"1320\"\u003e\nHART communication\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g65u6m\" data-start=\"1321\" data-end=\"1352\"\u003e\nSupply Voltage:\n\u003cul data-start=\"1341\" data-end=\"1352\"\u003e\n\u003cli data-section-id=\"dnfwma\" data-start=\"1341\" data-end=\"1352\"\u003e\n18–32 VDC\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1j4bbly\" data-start=\"1353\" data-end=\"1403\"\u003e\nResponse Time:\n\u003cul data-start=\"1372\" data-end=\"1403\"\u003e\n\u003cli data-section-id=\"4gd8kt\" data-start=\"1372\" data-end=\"1403\"\u003e\nTypically less than 3 seconds\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"h81dl9\" data-start=\"1404\" data-end=\"1467\"\u003e\nSelf Diagnostics:\n\u003cul data-start=\"1426\" data-end=\"1467\"\u003e\n\u003cli data-section-id=\"6ojcgo\" data-start=\"1426\" data-end=\"1467\"\u003e\nContinuous automatic optical monitoring\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yt389o\" data-start=\"1468\" data-end=\"1553\"\u003e\nHousing Material:\n\u003cul data-start=\"1490\" data-end=\"1553\"\u003e\n\u003cli data-section-id=\"vhbjij\" data-start=\"1490\" data-end=\"1553\"\u003e\nMarine-grade aluminium or stainless steel (version dependent)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ny50kf\" data-start=\"1554\" data-end=\"1590\"\u003e\nProtection Rating:\n\u003cul data-start=\"1577\" data-end=\"1590\"\u003e\n\u003cli data-section-id=\"lzypfq\" data-start=\"1577\" data-end=\"1590\"\u003e\nIP66 \/ IP67\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"yr8oaj\" data-start=\"1591\" data-end=\"1634\"\u003e\nOperating Temperature:\n\u003cul data-start=\"1618\" data-end=\"1634\"\u003e\n\u003cli data-section-id=\"xlkjb\" data-start=\"1618\" data-end=\"1634\"\u003e\n-55°C to +75°C\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"efztbo\" data-start=\"1635\" data-end=\"1696\"\u003e\nCertifications:\n\u003cul data-start=\"1655\" data-end=\"1696\"\u003e\n\u003cli data-section-id=\"1j42fog\" data-start=\"1655\" data-end=\"1661\"\u003e\nATEX\n\u003c\/li\u003e\n\u003cli data-section-id=\"16seo0q\" data-start=\"1664\" data-end=\"1671\"\u003e\nIECEx\n\u003c\/li\u003e\n\u003cli data-section-id=\"yhmtwj\" data-start=\"1674\" data-end=\"1678\"\u003e\nFM\n\u003c\/li\u003e\n\u003cli data-section-id=\"mlbwb8\" data-start=\"1681\" data-end=\"1696\"\u003e\nSIL 2 capable\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1212f2c\" data-start=\"1698\" data-end=\"1710\"\u003eFunction\u003c\/h3\u003e\n\u003cp data-start=\"1711\" data-end=\"2162\"\u003eThe GD10P continuously monitors the atmosphere for combustible hydrocarbon gases using infrared absorption technology. When gas enters the optical path, the detector measures the reduction in infrared energy caused by the gas molecules and converts this into a gas concentration reading. Unlike catalytic bead detectors, the GD10P is resistant to poisoning and contamination, providing long-term stable operation with minimal maintenance requirements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ucz99x\" data-start=\"2164\" data-end=\"2188\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2189\" data-end=\"2414\"\u003e\n\u003cli data-section-id=\"2vozqp\" data-start=\"2189\" data-end=\"2219\"\u003e\nOffshore oil \u0026amp; gas platforms\n\u003c\/li\u003e\n\u003cli data-section-id=\"2fb20m\" data-start=\"2220\" data-end=\"2232\"\u003e\nRefineries\n\u003c\/li\u003e\n\u003cli data-section-id=\"qa0u84\" data-start=\"2233\" data-end=\"2255\"\u003e\nPetrochemical plants\n\u003c\/li\u003e\n\u003cli data-section-id=\"r8n6gq\" data-start=\"2256\" data-end=\"2277\"\u003e\nCompressor stations\n\u003c\/li\u003e\n\u003cli data-section-id=\"q4azla\" data-start=\"2278\" data-end=\"2294\"\u003e\nLNG facilities\n\u003c\/li\u003e\n\u003cli data-section-id=\"hzc27m\" data-start=\"2295\" data-end=\"2315\"\u003e\nTurbine enclosures\n\u003c\/li\u003e\n\u003cli data-section-id=\"1f61jmq\" data-start=\"2316\" data-end=\"2339\"\u003e\nGas processing plants\n\u003c\/li\u003e\n\u003cli data-section-id=\"19su367\" data-start=\"2340\" data-end=\"2375\"\u003e\nChemical manufacturing facilities\n\u003c\/li\u003e\n\u003cli data-section-id=\"eg9cke\" data-start=\"2376\" data-end=\"2414\"\u003e\nHazardous area gas detection systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003eWe have a wide range of industrial items such as pressure transmitters, temperature transmitters, flow meters, and loads more!\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Contact Number: 07915071899\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Email: mdalrymple@stakam.co.uk\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e⸻\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eFull Specifications:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e• Manufacturer: Simtronics\u003c\/div\u003e\n\u003cdiv\u003e• Model: \u003c\/div\u003e\n\u003cdiv\u003eGD10-P00-17DG-0XH-00\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"379\" style=\"border-collapse:\n collapse;width:284pt\"\u003e\u003c\/table\u003e• Enclosure Rating: IP66\/67\u003c\/div\u003e\n\u003cdiv\u003e• Hazardous Area Certification:\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003eNemko 07ATEX1438 IECEx NEM 07.0006 II2G Ex d e IIC T6 Gb\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1108\" style=\"border-collapse:\n collapse;width:831pt\"\u003e\u003c\/table\u003e• ATEX Certified\u003c\/div\u003e\n\u003cdiv\u003e• IECEx Approved\u003c\/div\u003e\n\u003cdiv\u003eTerminal 1 +24 VDC, Terminal 2 0 V, Terminal 3 4-20 mA output, Terminal 4 \u0026amp; 5 factory use only\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"578\" style=\"border-collapse:\n collapse;width:434pt\"\u003e\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e⸻\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e✔ Used in great condition\u003c\/div\u003e\n\u003cdiv\u003e✔ Stored correctly in dry environment\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cb\u003eQuantity\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003eWe have 5 total units available.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Simtronics\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e P0017DG0XH00\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Simtronics","offers":[{"title":"Default Title","offer_id":53860579311944,"sku":"GT001","price":760.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0971\/6383\/7768\/files\/57_b136abd8-c0da-4a74-9b3c-8a712776b911.png?v=1787159782","url":"https:\/\/www.mstak.co.uk\/products\/simtronics-gas-detector-gd10p-p0017dg0xh00-1","provider":"MSTAK","version":"1.0","type":"link"}