{"product_id":"rosemount-pt100-temperature-transmitter-0065n30j0080n0450a2i1xaw0043-1","title":"Rosemount PT100 Temperature Transmitter 0065N30J0080N0450A2I1XAW0043","description":"\u003cp data-start=\"119\" data-end=\"769\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"123\" data-end=\"179\"\u003eRosemount 0065 Pt100 RTD Temperature Sensor Assembly\u003c\/strong\u003e is a high-accuracy industrial temperature measurement device designed for demanding process applications. Utilizing a platinum Pt100 resistance temperature detector (RTD) element, the Rosemount 0065 provides highly stable, repeatable, and accurate temperature measurement for use in chemical processing, oil \u0026amp; gas, power generation, food \u0026amp; beverage, pharmaceutical, and general industrial applications. The sensor is commonly paired with Rosemount temperature transmitters such as the 248, 644, and 3144P for complete temperature monitoring solutions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"771\" data-end=\"787\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"788\" data-end=\"1285\"\u003e\n\u003cli data-section-id=\"1ui3yu4\" data-start=\"788\" data-end=\"824\"\u003e\nPlatinum Pt100 RTD sensing element\n\u003c\/li\u003e\n\u003cli data-section-id=\"19i3x4s\" data-start=\"825\" data-end=\"864\"\u003e\nHigh accuracy and long-term stability\n\u003c\/li\u003e\n\u003cli data-section-id=\"bozczw\" data-start=\"865\" data-end=\"906\"\u003e\nDIN-style industrial temperature sensor\n\u003c\/li\u003e\n\u003cli data-section-id=\"8f9dbb\" data-start=\"907\" data-end=\"946\"\u003e\nMineral-insulated sensor construction\n\u003c\/li\u003e\n\u003cli data-section-id=\"wcwroy\" data-start=\"947\" data-end=\"999\"\u003e\nSuitable for direct or remote transmitter mounting\n\u003c\/li\u003e\n\u003cli data-section-id=\"1m61zel\" data-start=\"1000\" data-end=\"1032\"\u003e\nExcellent vibration resistance\n\u003c\/li\u003e\n\u003cli data-section-id=\"1apfgza\" data-start=\"1033\" data-end=\"1074\"\u003e\nFast sensor replacement and maintenance\n\u003c\/li\u003e\n\u003cli data-section-id=\"l33324\" data-start=\"1075\" data-end=\"1127\"\u003e\nCompatible with Rosemount temperature transmitters\n\u003c\/li\u003e\n\u003cli data-section-id=\"17vnr3i\" data-start=\"1128\" data-end=\"1186\"\u003e\nSuitable for hazardous and general-purpose installations\n\u003c\/li\u003e\n\u003cli data-section-id=\"6kxpff\" data-start=\"1187\" data-end=\"1285\"\u003e\nRobust stainless steel construction for harsh environments \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1287\" data-end=\"1305\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1306\" data-end=\"2005\"\u003e\n\u003cli data-section-id=\"1una9lb\" data-start=\"1306\" data-end=\"1341\"\u003e\nManufacturer: Rosemount (Emerson)\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ljhzjy\" data-start=\"1342\" data-end=\"1355\"\u003e\nModel: 0065\n\u003c\/li\u003e\n\u003cli data-section-id=\"1udmtro\" data-start=\"1356\" data-end=\"1404\"\u003e\nFull Part Number: 0065N30J0080N0450A2I1XAW0043\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cci4dk\" data-start=\"1405\" data-end=\"1432\"\u003e\nSensor Type: Platinum RTD\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tc1krd\" data-start=\"1433\" data-end=\"1449\"\u003e\nElement: Pt100\n\u003c\/li\u003e\n\u003cli data-section-id=\"eezv8f\" data-start=\"1450\" data-end=\"1476\"\u003e\nResistance: 100 Ω at 0°C\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bxwdmc\" data-start=\"1477\" data-end=\"1522\"\u003e\nTemperature Coefficient: α = 0.00385 Ω\/Ω\/°C\n\u003c\/li\u003e\n\u003cli data-section-id=\"183o4g2\" data-start=\"1523\" data-end=\"1597\"\u003e\nTemperature Range:\n\u003cul data-start=\"1546\" data-end=\"1597\"\u003e\n\u003cli data-section-id=\"1yiuevg\" data-start=\"1546\" data-end=\"1597\"\u003e\nUp to -196°C to +600°C depending on configuration\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"swqd25\" data-start=\"1598\" data-end=\"1667\"\u003e\nAccuracy:\n\u003cul data-start=\"1612\" data-end=\"1667\"\u003e\n\u003cli data-section-id=\"fy6qfx\" data-start=\"1612\" data-end=\"1667\"\u003e\nIEC 60751 Class A or Class B depending on option code\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"k0f7sn\" data-start=\"1668\" data-end=\"1712\"\u003e\nConstruction:\n\u003cul data-start=\"1686\" data-end=\"1712\"\u003e\n\u003cli data-section-id=\"728fhz\" data-start=\"1686\" data-end=\"1712\"\u003e\nMineral insulated sensor\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tduj7i\" data-start=\"1713\" data-end=\"1751\"\u003e\nSheath Material:\n\u003cul data-start=\"1734\" data-end=\"1751\"\u003e\n\u003cli data-section-id=\"18g4t1n\" data-start=\"1734\" data-end=\"1751\"\u003e\nStainless steel\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"yviabo\" data-start=\"1752\" data-end=\"1807\"\u003e\nInsulation Resistance:\n\u003cul data-start=\"1779\" data-end=\"1807\"\u003e\n\u003cli data-section-id=\"y5bjgq\" data-start=\"1779\" data-end=\"1807\"\u003e\nMinimum 1000 MΩ at 500 VDC\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hhj5xg\" data-start=\"1808\" data-end=\"1885\"\u003e\nResponse Time:\n\u003cul data-start=\"1827\" data-end=\"1885\"\u003e\n\u003cli data-section-id=\"sbs7j\" data-start=\"1827\" data-end=\"1885\"\u003e\nApproximately 9 seconds to 50% response in flowing water\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kkxjel\" data-start=\"1886\" data-end=\"2005\"\u003e\nConnection:\n\u003cul data-start=\"1902\" data-end=\"2005\"\u003e\n\u003cli data-section-id=\"7or8ye\" data-start=\"1902\" data-end=\"2005\"\u003e\nSuitable for use with terminal heads and Rosemount transmitters \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1212f2c\" data-start=\"2007\" data-end=\"2019\"\u003eFunction\u003c\/h3\u003e\n\u003cp data-start=\"2020\" data-end=\"2513\"\u003eThe Rosemount 0065 RTD measures temperature by monitoring the change in electrical resistance of a platinum sensing element. The highly linear Pt100 sensor provides precise temperature measurement across a wide operating range and converts process temperature into a resistance signal that can be transmitted to a temperature transmitter, PLC, DCS, or monitoring system. Its rugged design ensures reliable performance in demanding industrial environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"ucz99x\" data-start=\"2515\" data-end=\"2539\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2540\" data-end=\"2844\"\u003e\n\u003cli data-section-id=\"1pse6ai\" data-start=\"2540\" data-end=\"2562\"\u003e\nOil \u0026amp; gas processing\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nbop3s\" data-start=\"2563\" data-end=\"2580\"\u003e\nChemical plants\n\u003c\/li\u003e\n\u003cli data-section-id=\"17y4i9e\" data-start=\"2581\" data-end=\"2610\"\u003e\nPower generation facilities\n\u003c\/li\u003e\n\u003cli data-section-id=\"11eqzuy\" data-start=\"2611\" data-end=\"2639\"\u003e\nFood \u0026amp; beverage production\n\u003c\/li\u003e\n\u003cli data-section-id=\"oc50v\" data-start=\"2640\" data-end=\"2670\"\u003e\nPharmaceutical manufacturing\n\u003c\/li\u003e\n\u003cli data-section-id=\"71iqi0\" data-start=\"2671\" data-end=\"2703\"\u003e\nTank farms and storage vessels\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b04z4r\" data-start=\"2704\" data-end=\"2731\"\u003e\nSteam and utility systems\n\u003c\/li\u003e\n\u003cli data-section-id=\"1c802zn\" data-start=\"2732\" data-end=\"2760\"\u003e\nIndustrial process control\n\u003c\/li\u003e\n\u003cli data-section-id=\"748v9m\" data-start=\"2761\" data-end=\"2844\"\u003e\nGeneral temperature monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003eWe have a wide range of industrial items such as pressure transmitters, temperature transmitters, flow meters, and loads more!\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Contact Number: 07915071899\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Email: mdalrymple@stakam.co.uk\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e⸻\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eFull Specifications:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e• Manufacturer: Rosemount\u003c\/div\u003e\n\u003cdiv\u003e• Model: 0065N30J0080N0450A2I1XAW0043\u003c\/div\u003e\n\u003cdiv\u003e• Length of Sensor: 600mm\u003c\/div\u003e\n\u003cdiv\u003e• Hazardous Area Certification:\u003c\/div\u003e\n\u003cdiv\u003eIBExU 03ATEX 10.66X\u003c\/div\u003e\n\u003cdiv\u003e• ATEX Certified\u003c\/div\u003e\n\u003cdiv\u003e• IECEx Approved\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e⸻\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e✔ Brand new in original packaging\u003c\/div\u003e\n\u003cdiv\u003e✔ Stored correctly in dry environment\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cb\u003eQuantity\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003eWe have 3 total units available.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Rosemount\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e 0065N30J0080N0450A2I1XAW0043\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Rosemount","offers":[{"title":"Default Title","offer_id":53860579344712,"sku":"TT011","price":285.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0971\/6383\/7768\/files\/57_808eeef8-b06d-4486-9965-dc873f64fa7a.png?v=1787159787","url":"https:\/\/www.mstak.co.uk\/products\/rosemount-pt100-temperature-transmitter-0065n30j0080n0450a2i1xaw0043-1","provider":"MSTAK","version":"1.0","type":"link"}