{"product_id":"rosemount-e1151-pressure-transmitter-with-manifold-1","title":"Rosemount E1151 Pressure Transmitter with Manifold","description":"\u003cp data-start=\"74\" data-end=\"699\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"78\" data-end=\"117\"\u003eRosemount 1151 Pressure Transmitter\u003c\/strong\u003e is a rugged, industry-proven smart pressure transmitter designed for accurate measurement of differential pressure, gauge pressure, liquid level, flow, and process pressure in demanding industrial environments. Supplied with a valve manifold assembly, this transmitter allows convenient isolation, equalization, calibration, and maintenance without process shutdown. The Rosemount 1151 series became one of the most widely installed pressure transmitters in the oil \u0026amp; gas, chemical, power generation, and process industries due to its reliability, stability, and long service life.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"701\" data-end=\"717\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"718\" data-end=\"1066\"\u003e\n\u003cli data-section-id=\"4tzfie\" data-start=\"718\" data-end=\"753\"\u003e\nDifferential pressure measurement\n\u003c\/li\u003e\n\u003cli data-section-id=\"11v45cx\" data-start=\"754\" data-end=\"807\"\u003e\nSuitable for flow, level, and pressure applications\n\u003c\/li\u003e\n\u003cli data-section-id=\"16u6gjg\" data-start=\"808\" data-end=\"842\"\u003e\nIntegral valve manifold included\n\u003c\/li\u003e\n\u003cli data-section-id=\"o8qu22\" data-start=\"843\" data-end=\"869\"\u003e\nHigh long-term stability\n\u003c\/li\u003e\n\u003cli data-section-id=\"r0tl7f\" data-start=\"870\" data-end=\"896\"\u003e\nRugged industrial design\n\u003c\/li\u003e\n\u003cli data-section-id=\"7y7vu\" data-start=\"897\" data-end=\"923\"\u003e\nProven field reliability\n\u003c\/li\u003e\n\u003cli data-section-id=\"o3wv50\" data-start=\"924\" data-end=\"959\"\u003e\nStainless steel wetted components\n\u003c\/li\u003e\n\u003cli data-section-id=\"wy5xx0\" data-start=\"960\" data-end=\"987\"\u003e\nLow maintenance operation\n\u003c\/li\u003e\n\u003cli data-section-id=\"11h62rb\" data-start=\"988\" data-end=\"1031\"\u003e\nSuitable for hazardous area installations\n\u003c\/li\u003e\n\u003cli data-section-id=\"lxcu2a\" data-start=\"1032\" data-end=\"1066\"\u003e\nIndustry-standard 4–20 mA output\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1068\" data-end=\"1086\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1087\" data-end=\"1768\"\u003e\n\u003cli data-section-id=\"bn7077\" data-start=\"1087\" data-end=\"1112\"\u003e\nManufacturer: Rosemount\n\u003c\/li\u003e\n\u003cli data-section-id=\"b1tiq5\" data-start=\"1113\" data-end=\"1127\"\u003e\nSeries: 1151\n\u003c\/li\u003e\n\u003cli data-section-id=\"ickqtp\" data-start=\"1128\" data-end=\"1180\"\u003e\nType: Pressure \/ Differential Pressure Transmitter\n\u003c\/li\u003e\n\u003cli data-section-id=\"1glmkon\" data-start=\"1181\" data-end=\"1297\"\u003e\nMeasurement Types:\n\u003cul data-start=\"1204\" data-end=\"1297\"\u003e\n\u003cli data-section-id=\"no0l3g\" data-start=\"1204\" data-end=\"1227\"\u003e\nDifferential Pressure\n\u003c\/li\u003e\n\u003cli data-section-id=\"enh99u\" data-start=\"1230\" data-end=\"1244\"\u003e\nLiquid Level\n\u003c\/li\u003e\n\u003cli data-section-id=\"q7wxo0\" data-start=\"1247\" data-end=\"1265\"\u003e\nFlow Measurement\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ddx31m\" data-start=\"1268\" data-end=\"1297\"\u003e\nProcess Pressure Monitoring\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"150il2y\" data-start=\"1298\" data-end=\"1329\"\u003e\nOutput Signal:\n\u003cul data-start=\"1317\" data-end=\"1329\"\u003e\n\u003cli data-section-id=\"vm9eh2\" data-start=\"1317\" data-end=\"1329\"\u003e\n4–20 mA DC\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ldu6k9\" data-start=\"1330\" data-end=\"1359\"\u003e\nPower Supply:\n\u003cul data-start=\"1348\" data-end=\"1359\"\u003e\n\u003cli data-section-id=\"jxihfs\" data-start=\"1348\" data-end=\"1359\"\u003e\n12–45 VDC\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1a1p531\" data-start=\"1360\" data-end=\"1407\"\u003e\nAccuracy:\n\u003cul data-start=\"1374\" data-end=\"1407\"\u003e\n\u003cli data-section-id=\"1tju6d9\" data-start=\"1374\" data-end=\"1407\"\u003e\nUp to ±0.25% of calibrated span\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1asatgp\" data-start=\"1408\" data-end=\"1451\"\u003e\nWetted Materials:\n\u003cul data-start=\"1430\" data-end=\"1451\"\u003e\n\u003cli data-section-id=\"19l7yqn\" data-start=\"1430\" data-end=\"1451\"\u003e\n316 Stainless Steel\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"dabpi0\" data-start=\"1452\" data-end=\"1501\"\u003e\nProcess Connections:\n\u003cul data-start=\"1477\" data-end=\"1501\"\u003e\n\u003cli data-section-id=\"i9mh57\" data-start=\"1477\" data-end=\"1501\"\u003e\n1\/4\" NPT process ports\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qet41w\" data-start=\"1502\" data-end=\"1588\"\u003e\nManifold:\n\u003cul data-start=\"1516\" data-end=\"1588\"\u003e\n\u003cli data-section-id=\"1t496fn\" data-start=\"1516\" data-end=\"1588\"\u003e\n3-valve or 5-valve manifold configuration (depending on supplied unit)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"o84k\" data-start=\"1589\" data-end=\"1662\"\u003e\nOperating Temperature:\n\u003cul data-start=\"1616\" data-end=\"1662\"\u003e\n\u003cli data-section-id=\"1md7ii0\" data-start=\"1616\" data-end=\"1662\"\u003e\nSuitable for industrial process environments\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9lojm8\" data-start=\"1663\" data-end=\"1768\"\u003e\nCertifications:\n\u003cul data-start=\"1683\" data-end=\"1768\"\u003e\n\u003cli data-section-id=\"ff732e\" data-start=\"1683\" data-end=\"1768\"\u003e\nATEX, FM, CSA and IEC hazardous area approvals available depending on configuration\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1212f2c\" data-start=\"1770\" data-end=\"1782\"\u003eFunction\u003c\/h3\u003e\n\u003cp data-start=\"1783\" data-end=\"2279\"\u003eThe Rosemount 1151 measures pressure by sensing the differential force acting across an isolation diaphragm and converting this into a proportional 4–20 mA output signal. When installed across an orifice plate, venturi, or flow element, it can accurately measure flow. It can also be used for tank level measurement, filter monitoring, pump performance monitoring, and general process pressure applications. The included manifold simplifies commissioning, calibration, and maintenance operations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ucz99x\" data-start=\"2281\" data-end=\"2305\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2306\" data-end=\"2546\"\u003e\n\u003cli data-section-id=\"zkcwk2\" data-start=\"2306\" data-end=\"2328\"\u003e\nOil \u0026amp; gas production\n\u003c\/li\u003e\n\u003cli data-section-id=\"9z5czr\" data-start=\"2329\" data-end=\"2350\"\u003e\nChemical processing\n\u003c\/li\u003e\n\u003cli data-section-id=\"2fb20m\" data-start=\"2351\" data-end=\"2363\"\u003e\nRefineries\n\u003c\/li\u003e\n\u003cli data-section-id=\"1d7qzxt\" data-start=\"2364\" data-end=\"2382\"\u003e\nPower generation\n\u003c\/li\u003e\n\u003cli data-section-id=\"1lt0koj\" data-start=\"2383\" data-end=\"2415\"\u003e\nWater and wastewater treatment\n\u003c\/li\u003e\n\u003cli data-section-id=\"4bcsro\" data-start=\"2416\" data-end=\"2440\"\u003e\nTank level measurement\n\u003c\/li\u003e\n\u003cli data-section-id=\"1m3k152\" data-start=\"2441\" data-end=\"2467\"\u003e\nFlow measurement systems\n\u003c\/li\u003e\n\u003cli data-section-id=\"1crmlb4\" data-start=\"2468\" data-end=\"2509\"\u003e\nFilter differential pressure monitoring\n\u003c\/li\u003e\n\u003cli data-section-id=\"1t2ramt\" data-start=\"2510\" data-end=\"2546\"\u003e\nGeneral industrial process control\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003eWe have a wide range of industrial items such as pressure transmitters, temperature transmitters, flow meters, and loads more!\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Contact Number: 07915071899\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Email: mdalrymple@stakam.co.uk\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e⸻\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eFull Specifications:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e• Manufacturer: Rosemount Emerson\u003c\/div\u003e\n\u003cdiv\u003e• Model: E1151\u003c\/div\u003e\n\u003cdiv\u003e• Serial Number:\u003c\/div\u003e\n\u003cdiv\u003eE117302\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"237\" style=\"border-collapse:\n collapse;width:178pt\"\u003e\u003c\/table\u003e• Hazardous Area Certification:\u003c\/div\u003e\n\u003cdiv\u003eEEx ia IIC T5 EEx ia IIC T4\u003c\/div\u003e\n\u003cdiv\u003e• ATEX Certified\u003c\/div\u003e\n\u003cdiv\u003e• IECEx Approved\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e⸻\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e✔ Used in great condition\u003c\/div\u003e\n\u003cdiv\u003e✔ Stored correctly in dry environment\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Rosemount\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e E1151\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Rosemount","offers":[{"title":"Default Title","offer_id":53860579279176,"sku":"PT030","price":209.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0971\/6383\/7768\/files\/57_3a35ed43-aa3d-4340-bc91-5310806f4cde.png?v=1787159780","url":"https:\/\/www.mstak.co.uk\/products\/rosemount-e1151-pressure-transmitter-with-manifold-1","provider":"MSTAK","version":"1.0","type":"link"}