{"product_id":"pepperl-fuchs-kfd2-sr-ex1-isolated-switch-amplifier-34063s-1","title":"Pepperl+Fuchs KFD2-SR-Ex1 Isolated Switch Amplifier (34063S)","description":"\u003cp data-start=\"102\" data-end=\"495\" class=\"PDq2pG_selectionAnchorContainer\"\u003ehe \u003cstrong data-start=\"106\" data-end=\"135\"\u003ePepperl+Fuchs KFD2-SR-Ex1\u003c\/strong\u003e is an intrinsically safe isolated switch amplifier designed to transfer signals from NAMUR sensors and mechanical contacts in hazardous areas to control systems in safe areas. It provides reliable signal isolation, relay switching, and hazardous-area protection for industrial automation and process control applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"497\" data-end=\"513\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"514\" data-end=\"839\"\u003e\n\u003cli data-section-id=\"13dwf8u\" data-start=\"514\" data-end=\"551\"\u003e\nIntrinsically safe isolated barrier\n\u003c\/li\u003e\n\u003cli data-section-id=\"ptxj49\" data-start=\"552\" data-end=\"588\"\u003e\nNAMUR sensor and dry contact input\n\u003c\/li\u003e\n\u003cli data-section-id=\"3ft050\" data-start=\"589\" data-end=\"603\"\u003e\nRelay output\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ldv6wl\" data-start=\"604\" data-end=\"624\"\u003e\nGalvanic isolation\n\u003c\/li\u003e\n\u003cli data-section-id=\"1k842l1\" data-start=\"625\" data-end=\"651\"\u003e\nHazardous area certified\n\u003c\/li\u003e\n\u003cli data-section-id=\"frteb4\" data-start=\"652\" data-end=\"671\"\u003e\nDIN rail mounting\n\u003c\/li\u003e\n\u003cli data-section-id=\"1oanbga\" data-start=\"672\" data-end=\"699\"\u003e\nCompact industrial design\n\u003c\/li\u003e\n\u003cli data-section-id=\"32yrhc\" data-start=\"700\" data-end=\"741\"\u003e\nSuitable for process automation systems\n\u003c\/li\u003e\n\u003cli data-section-id=\"1g7mekh\" data-start=\"742\" data-end=\"839\"\u003e\nReliable signal transfer between hazardous and safe areas \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"841\" data-end=\"859\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"860\" data-end=\"1305\"\u003e\n\u003cli data-section-id=\"16j5rf\" data-start=\"860\" data-end=\"889\"\u003e\nManufacturer: Pepperl+Fuchs\n\u003c\/li\u003e\n\u003cli data-section-id=\"o3yoq3\" data-start=\"890\" data-end=\"910\"\u003e\nModel: KFD2-SR-Ex1\n\u003c\/li\u003e\n\u003cli data-section-id=\"5o3jev\" data-start=\"911\" data-end=\"932\"\u003e\nPart Number: 34063S\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nla784\" data-start=\"933\" data-end=\"966\"\u003e\nType: Isolated Switch Amplifier\n\u003c\/li\u003e\n\u003cli data-section-id=\"1h49ow\" data-start=\"967\" data-end=\"1015\"\u003e\nInput: NAMUR proximity sensors or dry contacts\n\u003c\/li\u003e\n\u003cli data-section-id=\"dekqi6\" data-start=\"1016\" data-end=\"1039\"\u003e\nOutput: Relay contact\n\u003c\/li\u003e\n\u003cli data-section-id=\"12yoj78\" data-start=\"1040\" data-end=\"1064\"\u003e\nSupply Voltage: 24 VDC\n\u003c\/li\u003e\n\u003cli data-section-id=\"ej7mcq\" data-start=\"1065\" data-end=\"1085\"\u003e\nMounting: DIN Rail\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nocdkg\" data-start=\"1086\" data-end=\"1151\"\u003e\nIsolation: Galvanic isolation between input, output, and supply\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pgrdrw\" data-start=\"1152\" data-end=\"1207\"\u003e\nHazardous Area Approval: Intrinsically Safe Interface\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pgrdrw\" data-start=\"1152\" data-end=\"1207\"\u003eEx PTB Nr. Ex-89.C.2073 [EEx ia] IIC\u003c\/li\u003e\n\u003cli data-section-id=\"15tqmad\" data-start=\"1208\" data-end=\"1305\"\u003e\nApplication: Signal transfer from hazardous to safe areas \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1212f2c\" data-start=\"1307\" data-end=\"1319\"\u003eFunction\u003c\/h3\u003e\n\u003cp data-start=\"1320\" data-end=\"1676\"\u003eThe KFD2-SR-Ex1 monitors switching signals from field devices located in hazardous areas and safely transfers them to PLCs, DCS systems, alarms, or other control equipment in the safe area. It is commonly used with NAMUR proximity sensors, limit switches, valve position indicators, and other discrete process signals. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"ucz99x\" data-start=\"1678\" data-end=\"1702\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"1703\" data-end=\"1912\"\u003e\n\u003cli data-section-id=\"1f6h0r5\" data-start=\"1703\" data-end=\"1714\"\u003e\nOil \u0026amp; Gas\n\u003c\/li\u003e\n\u003cli data-section-id=\"150dgx3\" data-start=\"1715\" data-end=\"1736\"\u003e\nChemical Processing\n\u003c\/li\u003e\n\u003cli data-section-id=\"2fb20m\" data-start=\"1737\" data-end=\"1749\"\u003e\nRefineries\n\u003c\/li\u003e\n\u003cli data-section-id=\"ja4efv\" data-start=\"1750\" data-end=\"1773\"\u003e\nPharmaceutical Plants\n\u003c\/li\u003e\n\u003cli data-section-id=\"elt2ft\" data-start=\"1774\" data-end=\"1791\"\u003e\nWater Treatment\n\u003c\/li\u003e\n\u003cli data-section-id=\"jg8beb\" data-start=\"1792\" data-end=\"1804\"\u003e\nTank Farms\n\u003c\/li\u003e\n\u003cli data-section-id=\"19qviik\" data-start=\"1805\" data-end=\"1825\"\u003e\nProcess Automation\n\u003c\/li\u003e\n\u003cli data-section-id=\"12j74r9\" data-start=\"1826\" data-end=\"1853\"\u003e\nValve Position Monitoring\n\u003c\/li\u003e\n\u003cli data-section-id=\"ovibs3\" data-start=\"1854\" data-end=\"1879\"\u003e\nLimit Switch Monitoring\n\u003c\/li\u003e\n\u003cli data-section-id=\"gcitx6\" data-start=\"1880\" data-end=\"1912\"\u003e\nHazardous Area Instrumentation\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uef3h1\" data-start=\"1914\" data-end=\"1927\"\u003eCondition\u003c\/h3\u003e\n\u003cp data-start=\"1928\" data-end=\"2083\"\u003eUsed industrial surplus. Removed from a working environment. Please review all photographs carefully for condition, model number, and included accessories.\u003c\/p\u003e\u003ch3 data-section-id=\"1uef3h1\" data-start=\"1914\" data-end=\"1927\"\u003eContact\u003c\/h3\u003e\u003cdiv\u003e\n\u003cdiv\u003eWe have a wide range of industrial items such as pressure transmitters, temperature transmitters, flow meters, and loads more!\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Contact Number: 07915071899\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Email: mdalrymple@stakam.co.uk\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003ch3 data-section-id=\"1uef3h1\" data-start=\"1914\" data-end=\"1927\"\u003eQuantity\u003c\/h3\u003e\u003c\/div\u003e\u003cdiv\u003eWe have 12 total units available, all near new condition.\u003c\/div\u003e\u003cp data-start=\"1928\" data-end=\"2083\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Pepperl\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Pepperl","offers":[{"title":"Default Title","offer_id":53860584292680,"sku":"34063S","price":60.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0971\/6383\/7768\/files\/57_cb984f84-f504-4242-998f-aa68d1cbbdd1.png?v=1787159883","url":"https:\/\/www.mstak.co.uk\/products\/pepperl-fuchs-kfd2-sr-ex1-isolated-switch-amplifier-34063s-1","provider":"MSTAK","version":"1.0","type":"link"}