{"product_id":"krohne-optimass-7300c-h10-coriolis-mass-flowmeter-1","title":"Krohne OPTIMASS 7300C H10 Coriolis Mass Flowmeter","description":"\u003cp data-start=\"74\" data-end=\"623\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"78\" data-end=\"107\"\u003eKROHNE OPTIMASS 7300C H10\u003c\/strong\u003e is a high-precision Coriolis mass flowmeter designed for direct measurement of \u003cstrong data-start=\"187\" data-end=\"239\"\u003emass flow, density, temperature, and volume flow\u003c\/strong\u003e in liquids and gases. Featuring a robust twin straight-tube sensor design, the OPTIMASS 7300C delivers exceptional accuracy and repeatability while remaining unaffected by changes in viscosity, pressure, temperature, conductivity, or fluid density. It is widely used in chemical processing, food \u0026amp; beverage, pharmaceutical production, oil \u0026amp; gas, and industrial batching applications.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"625\" data-end=\"641\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"642\" data-end=\"1094\"\u003e\n\u003cli data-section-id=\"1xukcno\" data-start=\"642\" data-end=\"685\"\u003e\nCoriolis mass flow measurement technology\n\u003c\/li\u003e\n\u003cli data-section-id=\"1u749u6\" data-start=\"686\" data-end=\"742\"\u003e\nDirect mass flow, density, and temperature measurement\n\u003c\/li\u003e\n\u003cli data-section-id=\"1c03oeb\" data-start=\"743\" data-end=\"780\"\u003e\nTwin straight measuring tube design\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mk98h1\" data-start=\"781\" data-end=\"814\"\u003e\nHigh accuracy and repeatability\n\u003c\/li\u003e\n\u003cli data-section-id=\"dyeta8\" data-start=\"815\" data-end=\"858\"\u003e\nSuitable for liquids, gases, and slurries\n\u003c\/li\u003e\n\u003cli data-section-id=\"w3989o\" data-start=\"859\" data-end=\"900\"\u003e\nNo moving parts for minimal maintenance\n\u003c\/li\u003e\n\u003cli data-section-id=\"6tyghi\" data-start=\"901\" data-end=\"949\"\u003e\nSimultaneous mass flow and density measurement\n\u003c\/li\u003e\n\u003cli data-section-id=\"i7s4d2\" data-start=\"950\" data-end=\"1003\"\u003e\nExcellent performance with difficult process fluids\n\u003c\/li\u003e\n\u003cli data-section-id=\"tqlw0v\" data-start=\"1004\" data-end=\"1036\"\u003e\nRobust industrial construction\n\u003c\/li\u003e\n\u003cli data-section-id=\"o7fn9w\" data-start=\"1037\" data-end=\"1094\"\u003e\nSuitable for custody transfer and batching applications\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1096\" data-end=\"1114\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1115\" data-end=\"1891\"\u003e\n\u003cli data-section-id=\"1ermp74\" data-start=\"1115\" data-end=\"1137\"\u003e\nManufacturer: KROHNE\n\u003c\/li\u003e\n\u003cli data-section-id=\"coj9uo\" data-start=\"1138\" data-end=\"1162\"\u003e\nSeries: OPTIMASS 7300C\n\u003c\/li\u003e\n\u003cli data-section-id=\"iypawk\" data-start=\"1163\" data-end=\"1175\"\u003e\nModel: H10\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ea17se\" data-start=\"1176\" data-end=\"1220\"\u003e\nTechnology: Coriolis Mass Flow Measurement\n\u003c\/li\u003e\n\u003cli data-section-id=\"1n1cqvt\" data-start=\"1221\" data-end=\"1303\"\u003e\nMeasurement Functions:\n\u003cul data-start=\"1248\" data-end=\"1303\"\u003e\n\u003cli data-section-id=\"13gan7a\" data-start=\"1248\" data-end=\"1259\"\u003e\nMass Flow\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ndjl0w\" data-start=\"1262\" data-end=\"1271\"\u003e\nDensity\n\u003c\/li\u003e\n\u003cli data-section-id=\"1f3vflw\" data-start=\"1274\" data-end=\"1287\"\u003e\nTemperature\n\u003c\/li\u003e\n\u003cli data-section-id=\"1erahea\" data-start=\"1290\" data-end=\"1303\"\u003e\nVolume Flow\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1en3xvx\" data-start=\"1304\" data-end=\"1375\"\u003e\nAccuracy:\n\u003cul data-start=\"1318\" data-end=\"1375\"\u003e\n\u003cli data-section-id=\"em1bc9\" data-start=\"1318\" data-end=\"1342\"\u003e\nMass Flow: up to ±0.1%\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qv3y6j\" data-start=\"1345\" data-end=\"1375\"\u003e\nDensity: up to ±0.0005 g\/cm³\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15413h9\" data-start=\"1376\" data-end=\"1440\"\u003e\nProcess Connection:\n\u003cul data-start=\"1400\" data-end=\"1440\"\u003e\n\u003cli data-section-id=\"alj1i5\" data-start=\"1400\" data-end=\"1440\"\u003e\nFlanged configuration (varies by unit)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"vvl89a\" data-start=\"1441\" data-end=\"1479\"\u003e\nWetted Material:\n\u003cul data-start=\"1462\" data-end=\"1479\"\u003e\n\u003cli data-section-id=\"17pe31n\" data-start=\"1462\" data-end=\"1479\"\u003e\nStainless Steel\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19q5pvx\" data-start=\"1480\" data-end=\"1617\"\u003e\nOutput Signals:\n\u003cul data-start=\"1500\" data-end=\"1617\"\u003e\n\u003cli data-section-id=\"1sapu81\" data-start=\"1500\" data-end=\"1509\"\u003e\n4–20 mA\n\u003c\/li\u003e\n\u003cli data-section-id=\"1f6v8qr\" data-start=\"1512\" data-end=\"1536\"\u003e\nPulse\/Frequency Output\n\u003c\/li\u003e\n\u003cli data-section-id=\"y5mr5z\" data-start=\"1539\" data-end=\"1559\"\u003e\nHART Communication\n\u003c\/li\u003e\n\u003cli data-section-id=\"1almfzc\" data-start=\"1562\" data-end=\"1617\"\u003e\nFieldbus options available depending on configuration\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15hptwp\" data-start=\"1618\" data-end=\"1681\"\u003e\nOperating Pressure:\n\u003cul data-start=\"1642\" data-end=\"1681\"\u003e\n\u003cli data-section-id=\"1x0gnvw\" data-start=\"1642\" data-end=\"1681\"\u003e\nUp to 100 bar (application dependent)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"bvi1g6\" data-start=\"1682\" data-end=\"1746\"\u003e\nProcess Temperature:\n\u003cul data-start=\"1707\" data-end=\"1746\"\u003e\n\u003cli data-section-id=\"1aok30s\" data-start=\"1707\" data-end=\"1746\"\u003e\nUp to 180°C (configuration dependent)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"iioz90\" data-start=\"1747\" data-end=\"1804\"\u003e\nProtection Rating:\n\u003cul data-start=\"1770\" data-end=\"1804\"\u003e\n\u003cli data-section-id=\"svfggd\" data-start=\"1770\" data-end=\"1804\"\u003e\nIP67 \/ IP68 depending on version\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dhk4wj\" data-start=\"1805\" data-end=\"1891\"\u003e\nHazardous Area Approvals:\n\u003cul data-start=\"1835\" data-end=\"1891\"\u003e\n\u003cli data-section-id=\"1xcj10g\" data-start=\"1835\" data-end=\"1891\"\u003e\nATEX, IECEx, FM approvals available on selected models\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1212f2c\" data-start=\"1893\" data-end=\"1905\"\u003eFunction\u003c\/h3\u003e\n\u003cp data-start=\"1906\" data-end=\"2332\"\u003eThe OPTIMASS 7300C measures flow using the Coriolis principle. As fluid passes through vibrating measuring tubes, the Coriolis effect causes a phase shift proportional to the mass flow rate. The instrument simultaneously calculates density from the tube vibration characteristics and measures process temperature using integrated sensors. This allows multiple process variables to be measured accurately using a single device.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ucz99x\" data-start=\"2334\" data-end=\"2358\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2359\" data-end=\"2625\"\u003e\n\u003cli data-section-id=\"9z5czr\" data-start=\"2359\" data-end=\"2380\"\u003e\nChemical processing\n\u003c\/li\u003e\n\u003cli data-section-id=\"zkcwk2\" data-start=\"2381\" data-end=\"2403\"\u003e\nOil \u0026amp; gas production\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nw7h9g\" data-start=\"2404\" data-end=\"2437\"\u003e\nFood and beverage manufacturing\n\u003c\/li\u003e\n\u003cli data-section-id=\"s7icrw\" data-start=\"2438\" data-end=\"2465\"\u003e\nPharmaceutical production\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o4j88m\" data-start=\"2466\" data-end=\"2492\"\u003e\nCustody transfer systems\n\u003c\/li\u003e\n\u003cli data-section-id=\"yw6vp4\" data-start=\"2493\" data-end=\"2527\"\u003e\nBlending and batching operations\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mqu43s\" data-start=\"2528\" data-end=\"2556\"\u003e\nTank loading and unloading\n\u003c\/li\u003e\n\u003cli data-section-id=\"mjei5u\" data-start=\"2557\" data-end=\"2582\"\u003e\nProcess control systems\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ce0xgr\" data-start=\"2583\" data-end=\"2625\"\u003e\nHigh-accuracy liquid dosing applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003eWe have a wide range of industrial items such as pressure transmitters, temperature transmitters, flow meters, and loads more!\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Contact Number: 07915071899\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Email: mdalrymple@stakam.co.uk\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e⸻\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eFull Specifications:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e• Manufacturer: Krohne\u003c\/div\u003e\n\u003cdiv\u003e• Model: OPTIMASS 7300C H10\u003c\/div\u003e\n\u003cdiv\u003e• Enclosure Rating: IP67\u003c\/div\u003e\n\u003cdiv\u003e• Hazardous Area Certification:\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003eEx II 1\/2(1) G Ex de [ia\/ib] II 2(1) D Ex 1 [ia]\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1108\" style=\"border-collapse:\n collapse;width:831pt\"\u003e\u003c\/table\u003e• ATEX Certified\u003c\/div\u003e\n\u003cdiv\u003e• IECEx Approved\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e⸻\u003c\/div\u003e\n\u003cdiv\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cb\u003eCondition:\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e✔ Used in great condition\u003c\/div\u003e\n\u003cdiv\u003e✔ Stored correctly in dry environment\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Krohne\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e 7300C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Krohne","offers":[{"title":"Default Title","offer_id":53860578951496,"sku":"FM021","price":1255.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0971\/6383\/7768\/files\/57_aae548ef-f22f-447e-85f3-6da066b8bc5c.png?v=1787159772","url":"https:\/\/www.mstak.co.uk\/products\/krohne-optimass-7300c-h10-coriolis-mass-flowmeter-1","provider":"MSTAK","version":"1.0","type":"link"}