{"product_id":"honeywell-xnx-xnxamse-nnnnn-universal-transmitter-1","title":"Honeywell XNX XNXAMSE-NNNNN Universal Transmitter","description":"\u003cp data-start=\"73\" data-end=\"598\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"77\" data-end=\"116\"\u003eHoneywell XNX Universal Transmitter\u003c\/strong\u003e is a highly flexible fixed gas detection platform designed to operate with a wide range of Honeywell gas sensing technologies, including electrochemical, infrared, catalytic bead, and open-path gas detectors. Commonly installed in oil \u0026amp; gas, petrochemical, offshore, chemical processing, power generation, and industrial manufacturing facilities, the XNX provides reliable monitoring of combustible, toxic, and oxygen gases in hazardous areas. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"600\" data-end=\"616\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"617\" data-end=\"1202\"\u003e\n\u003cli data-section-id=\"1blbhxx\" data-start=\"617\" data-end=\"659\"\u003e\nUniversal fixed gas detector transmitter\n\u003c\/li\u003e\n\u003cli data-section-id=\"angbr9\" data-start=\"660\" data-end=\"737\"\u003e\nCompatible with electrochemical, infrared, catalytic, and open-path sensors\n\u003c\/li\u003e\n\u003cli data-section-id=\"hsx4lo\" data-start=\"738\" data-end=\"784\"\u003e\nDetects combustible, toxic, and oxygen gases\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ozr8r5\" data-start=\"785\" data-end=\"841\"\u003e\nLarge backlit LCD display with local status indication\n\u003c\/li\u003e\n\u003cli data-section-id=\"1osdfs5\" data-start=\"842\" data-end=\"897\"\u003e\nModular design for easy maintenance and configuration\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pf1s9l\" data-start=\"898\" data-end=\"945\"\u003e\n4–20 mA analog output with HART communication\n\u003c\/li\u003e\n\u003cli data-section-id=\"l8bnoy\" data-start=\"946\" data-end=\"1010\"\u003e\nOptional relay, Modbus, and Foundation Fieldbus communications\n\u003c\/li\u003e\n\u003cli data-section-id=\"sjgzek\" data-start=\"1011\" data-end=\"1065\"\u003e\nHazardous area certified for worldwide installations\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nsh400\" data-start=\"1066\" data-end=\"1105\"\u003e\nNon-intrusive magnetic wand operation\n\u003c\/li\u003e\n\u003cli data-section-id=\"v3p2rk\" data-start=\"1106\" data-end=\"1202\"\u003e\nSupports a wide range of Honeywell Analytics gas sensors \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1204\" data-end=\"1222\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1223\" data-end=\"2050\"\u003e\n\u003cli data-section-id=\"1eug34k\" data-start=\"1223\" data-end=\"1258\"\u003e\nManufacturer: Honeywell Analytics\n\u003c\/li\u003e\n\u003cli data-section-id=\"7out2v\" data-start=\"1259\" data-end=\"1293\"\u003e\nModel: XNX Universal Transmitter\n\u003c\/li\u003e\n\u003cli data-section-id=\"dwtb1r\" data-start=\"1294\" data-end=\"1333\"\u003e\nType: Fixed Gas Detection Transmitter\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ayr224\" data-start=\"1334\" data-end=\"1419\"\u003e\nGas Types:\n\u003cul data-start=\"1349\" data-end=\"1419\"\u003e\n\u003cli data-section-id=\"1df7tgr\" data-start=\"1349\" data-end=\"1381\"\u003e\nCombustible gases (0–100% LEL)\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mra71e\" data-start=\"1384\" data-end=\"1397\"\u003e\nToxic gases\n\u003c\/li\u003e\n\u003cli data-section-id=\"tr2w4m\" data-start=\"1400\" data-end=\"1419\"\u003e\nOxygen monitoring\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1sawo09\" data-start=\"1420\" data-end=\"1545\"\u003e\nSensor Technologies Supported:\n\u003cul data-start=\"1455\" data-end=\"1545\"\u003e\n\u003cli data-section-id=\"1snrykt\" data-start=\"1455\" data-end=\"1477\"\u003e\nElectrochemical (EC)\n\u003c\/li\u003e\n\u003cli data-section-id=\"1sfc88j\" data-start=\"1480\" data-end=\"1495\"\u003e\nInfrared (IR)\n\u003c\/li\u003e\n\u003cli data-section-id=\"clbue\" data-start=\"1498\" data-end=\"1514\"\u003e\nCatalytic bead\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rc9c8b\" data-start=\"1517\" data-end=\"1545\"\u003e\nOpen-path infrared systems\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kgmpom\" data-start=\"1546\" data-end=\"1666\"\u003e\nOutput Signals:\n\u003cul data-start=\"1566\" data-end=\"1666\"\u003e\n\u003cli data-section-id=\"1sapu81\" data-start=\"1566\" data-end=\"1575\"\u003e\n4–20 mA\n\u003c\/li\u003e\n\u003cli data-section-id=\"uf8e41\" data-start=\"1578\" data-end=\"1593\"\u003e\nHART Protocol\n\u003c\/li\u003e\n\u003cli data-section-id=\"u82bj8\" data-start=\"1596\" data-end=\"1613\"\u003e\nOptional Modbus\n\u003c\/li\u003e\n\u003cli data-section-id=\"185g1xn\" data-start=\"1616\" data-end=\"1646\"\u003e\nOptional Foundation Fieldbus\n\u003c\/li\u003e\n\u003cli data-section-id=\"13wm91y\" data-start=\"1649\" data-end=\"1666\"\u003e\nOptional Relays\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hximxf\" data-start=\"1667\" data-end=\"1734\"\u003e\nDisplay:\n\u003cul data-start=\"1680\" data-end=\"1734\"\u003e\n\u003cli data-section-id=\"1s64qac\" data-start=\"1680\" data-end=\"1734\"\u003e\nHigh-resolution LCD with alarm and status indication\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4wxc2w\" data-start=\"1735\" data-end=\"1797\"\u003e\nOperating Temperature:\n\u003cul data-start=\"1762\" data-end=\"1797\"\u003e\n\u003cli data-section-id=\"az9ep0\" data-start=\"1762\" data-end=\"1797\"\u003e\n-40°C to +65°C (sensor dependent)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"36mzul\" data-start=\"1798\" data-end=\"1879\"\u003e\nHousing Materials:\n\u003cul data-start=\"1821\" data-end=\"1879\"\u003e\n\u003cli data-section-id=\"d3pknb\" data-start=\"1821\" data-end=\"1844\"\u003e\nPainted LM25 Aluminum\n\u003c\/li\u003e\n\u003cli data-section-id=\"oy185t\" data-start=\"1847\" data-end=\"1879\"\u003e\nOptional SS316 Stainless Steel\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1x80440\" data-start=\"1880\" data-end=\"1925\"\u003e\nMounting:\n\u003cul data-start=\"1894\" data-end=\"1925\"\u003e\n\u003cli data-section-id=\"1t23ckg\" data-start=\"1894\" data-end=\"1925\"\u003e\nWall, pipe, or field mounting\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1aa8dv4\" data-start=\"1926\" data-end=\"2050\"\u003e\nHazardous Area Approvals:\n\u003cul data-start=\"1956\" data-end=\"2050\"\u003e\n\u003cli data-section-id=\"1j42fog\" data-start=\"1956\" data-end=\"1962\"\u003e\nATEX\n\u003c\/li\u003e\n\u003cli data-section-id=\"16seo0q\" data-start=\"1965\" data-end=\"1972\"\u003e\nIECEx\n\u003c\/li\u003e\n\u003cli data-section-id=\"yhmua9\" data-start=\"1975\" data-end=\"1979\"\u003e\nUL\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o4e3d\" data-start=\"1982\" data-end=\"1987\"\u003e\nCSA\n\u003c\/li\u003e\n\u003cli data-section-id=\"15m2esx\" data-start=\"1990\" data-end=\"2050\"\u003e\nFM (model dependent) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1212f2c\" data-start=\"2052\" data-end=\"2064\"\u003eFunction\u003c\/h3\u003e\n\u003cp data-start=\"2065\" data-end=\"2540\"\u003eThe Honeywell XNX acts as the central transmitter for fixed gas detection systems. It receives signals from connected gas sensors, continuously monitors gas concentrations, displays readings locally, and transmits alarm and measurement data to plant control systems. Its universal architecture allows users to standardize on a single transmitter platform while supporting multiple sensor technologies and gas types throughout a facility. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"ucz99x\" data-start=\"2542\" data-end=\"2566\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2567\" data-end=\"2839\"\u003e\n\u003cli data-section-id=\"1evjtht\" data-start=\"2567\" data-end=\"2600\"\u003e\nOil \u0026amp; Gas Production Facilities\n\u003c\/li\u003e\n\u003cli data-section-id=\"19qjseg\" data-start=\"2601\" data-end=\"2621\"\u003e\nOffshore Platforms\n\u003c\/li\u003e\n\u003cli data-section-id=\"19rxq04\" data-start=\"2622\" data-end=\"2644\"\u003e\nPetrochemical Plants\n\u003c\/li\u003e\n\u003cli data-section-id=\"3gp2v8\" data-start=\"2645\" data-end=\"2677\"\u003e\nChemical Processing Facilities\n\u003c\/li\u003e\n\u003cli data-section-id=\"2fb20m\" data-start=\"2678\" data-end=\"2690\"\u003e\nRefineries\n\u003c\/li\u003e\n\u003cli data-section-id=\"pok8pm\" data-start=\"2691\" data-end=\"2706\"\u003e\nLNG Terminals\n\u003c\/li\u003e\n\u003cli data-section-id=\"qvveo5\" data-start=\"2707\" data-end=\"2732\"\u003e\nPower Generation Plants\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q0rp6\" data-start=\"2733\" data-end=\"2761\"\u003e\nWater Treatment Facilities\n\u003c\/li\u003e\n\u003cli data-section-id=\"u9e2ps\" data-start=\"2762\" data-end=\"2839\"\u003e\nHazardous Area Gas Monitoring Systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003eWe have a wide range of industrial items such as pressure transmitters, temperature transmitters, flow meters, and loads more!\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Contact Number: 07915071899\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Email: mdalrymple@stakam.co.uk\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e⸻\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e✔ Slightly used in great condition\u003c\/div\u003e\n\u003cdiv\u003e✔ Stored correctly in dry environment\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e XNXAMSE-NNNNN\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53860580131144,"sku":"UT001","price":570.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0971\/6383\/7768\/files\/57_bc3f9617-354f-44b2-9c31-7c86bd73828a.png?v=1787159813","url":"https:\/\/www.mstak.co.uk\/products\/honeywell-xnx-xnxamse-nnnnn-universal-transmitter-1","provider":"MSTAK","version":"1.0","type":"link"}