{"product_id":"abb-copa-xe-electromagnetic-flowmeter-1","title":"ABB COPA-XE Electromagnetic Flowmeter","description":"\u003cp data-start=\"62\" data-end=\"651\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"66\" data-end=\"107\"\u003eABB COPA-XE Electromagnetic Flowmeter\u003c\/strong\u003e is a high-performance compact magmeter designed for accurate flow measurement of electrically conductive liquids, slurries, pulps, and wastewater. Combining the flow sensor and converter into a single compact unit, the COPA-XE provides reliable, maintenance-free flow monitoring with no moving parts, minimal pressure loss, and excellent resistance to wear, abrasion, and chemical attack. It is widely used throughout the water treatment, chemical, food \u0026amp; beverage, pharmaceutical, and process industries. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"653\" data-end=\"669\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"670\" data-end=\"1171\"\u003e\n\u003cli data-section-id=\"1xgn2h8\" data-start=\"670\" data-end=\"725\"\u003e\nElectromagnetic (magnetic inductive) flow measurement\n\u003c\/li\u003e\n\u003cli data-section-id=\"j5vaw9\" data-start=\"726\" data-end=\"765\"\u003e\nCompact sensor and transmitter design\n\u003c\/li\u003e\n\u003cli data-section-id=\"18qfpdf\" data-start=\"766\" data-end=\"814\"\u003e\nNo moving parts for maintenance-free operation\n\u003c\/li\u003e\n\u003cli data-section-id=\"9bc6u3\" data-start=\"815\" data-end=\"843\"\u003e\nVirtually no pressure loss\n\u003c\/li\u003e\n\u003cli data-section-id=\"17o2x98\" data-start=\"844\" data-end=\"903\"\u003e\nSuitable for conductive liquids, slurries, and wastewater\n\u003c\/li\u003e\n\u003cli data-section-id=\"e1rjkh\" data-start=\"904\" data-end=\"931\"\u003e\nHigh measurement accuracy\n\u003c\/li\u003e\n\u003cli data-section-id=\"687l1v\" data-start=\"932\" data-end=\"964\"\u003e\nBidirectional flow measurement\n\u003c\/li\u003e\n\u003cli data-section-id=\"1msvn4q\" data-start=\"965\" data-end=\"1002\"\u003e\nResistant to abrasion and corrosion\n\u003c\/li\u003e\n\u003cli data-section-id=\"1v1g7za\" data-start=\"1003\" data-end=\"1042\"\u003e\nMultifunction display and diagnostics\n\u003c\/li\u003e\n\u003cli data-section-id=\"1jku5mj\" data-start=\"1043\" data-end=\"1171\"\u003e\nAvailable with HART, Profibus and other communication options depending on configuration \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1173\" data-end=\"1191\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1192\" data-end=\"2019\"\u003e\n\u003cli data-section-id=\"1ypcick\" data-start=\"1192\" data-end=\"1211\"\u003e\nManufacturer: ABB\n\u003c\/li\u003e\n\u003cli data-section-id=\"fgd2mc\" data-start=\"1212\" data-end=\"1229\"\u003e\nSeries: COPA-XE\n\u003c\/li\u003e\n\u003cli data-section-id=\"18erk2c\" data-start=\"1230\" data-end=\"1276\"\u003e\nTechnology: Electromagnetic Flow Measurement\n\u003c\/li\u003e\n\u003cli data-section-id=\"jke7rk\" data-start=\"1277\" data-end=\"1313\"\u003e\nDesign: Compact Integral Flowmeter\n\u003c\/li\u003e\n\u003cli data-section-id=\"1kq77jk\" data-start=\"1314\" data-end=\"1389\"\u003e\nConductivity Requirement:\n\u003cul data-start=\"1344\" data-end=\"1389\"\u003e\n\u003cli data-section-id=\"1f2d819\" data-start=\"1344\" data-end=\"1389\"\u003e\n\u003cblockquote data-start=\"1346\" data-end=\"1389\"\u003e\n\u003cp data-start=\"1347\" data-end=\"1389\"\u003e5 µS\/cm (20 µS\/cm for demineralized water)\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1oa920y\" data-start=\"1390\" data-end=\"1425\"\u003e\nAccuracy:\n\u003cul data-start=\"1404\" data-end=\"1425\"\u003e\n\u003cli data-section-id=\"1dsu43m\" data-start=\"1404\" data-end=\"1425\"\u003e\nUp to ±0.5% of rate\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"u221vc\" data-start=\"1426\" data-end=\"1479\"\u003e\nFlow Direction:\n\u003cul data-start=\"1446\" data-end=\"1479\"\u003e\n\u003cli data-section-id=\"1fagk8i\" data-start=\"1446\" data-end=\"1479\"\u003e\nForward and Reverse Measurement\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zqg9p3\" data-start=\"1480\" data-end=\"1572\"\u003e\nOutput Signals:\n\u003cul data-start=\"1500\" data-end=\"1572\"\u003e\n\u003cli data-section-id=\"1sapu81\" data-start=\"1500\" data-end=\"1509\"\u003e\n4–20 mA\n\u003c\/li\u003e\n\u003cli data-section-id=\"x6o4so\" data-start=\"1512\" data-end=\"1526\"\u003e\nPulse Output\n\u003c\/li\u003e\n\u003cli data-section-id=\"2wh25t\" data-start=\"1529\" data-end=\"1572\"\u003e\nHART \/ Profibus options (model dependent)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ih5ru1\" data-start=\"1573\" data-end=\"1602\"\u003e\nProtection Rating:\n\u003cul data-start=\"1596\" data-end=\"1602\"\u003e\n\u003cli data-section-id=\"1j3w74g\" data-start=\"1596\" data-end=\"1602\"\u003e\nIP67\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ru6xv3\" data-start=\"1603\" data-end=\"1687\"\u003e\nProcess Connections:\n\u003cul data-start=\"1628\" data-end=\"1687\"\u003e\n\u003cli data-section-id=\"12bpxu3\" data-start=\"1628\" data-end=\"1637\"\u003e\nFlanged\n\u003c\/li\u003e\n\u003cli data-section-id=\"17bfcz3\" data-start=\"1640\" data-end=\"1647\"\u003e\nWafer\n\u003c\/li\u003e\n\u003cli data-section-id=\"1adqmt4\" data-start=\"1650\" data-end=\"1687\"\u003e\nHygienic process fittings available\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14eoqv1\" data-start=\"1688\" data-end=\"1747\"\u003e\nLiner Materials:\n\u003cul data-start=\"1709\" data-end=\"1747\"\u003e\n\u003cli data-section-id=\"1j4acj3\" data-start=\"1709\" data-end=\"1715\"\u003e\nPTFE\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o4oqn\" data-start=\"1718\" data-end=\"1723\"\u003e\nPFA\n\u003c\/li\u003e\n\u003cli data-section-id=\"1uik27o\" data-start=\"1726\" data-end=\"1747\"\u003e\nHard or Soft Rubber\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6dzjer\" data-start=\"1748\" data-end=\"1875\"\u003e\nElectrode Materials:\n\u003cul data-start=\"1773\" data-end=\"1875\"\u003e\n\u003cli data-section-id=\"1dppjxe\" data-start=\"1773\" data-end=\"1796\"\u003e\n316Ti Stainless Steel\n\u003c\/li\u003e\n\u003cli data-section-id=\"18y9ho5\" data-start=\"1799\" data-end=\"1810\"\u003e\nHastelloy\n\u003c\/li\u003e\n\u003cli data-section-id=\"1v8k7lr\" data-start=\"1813\" data-end=\"1823\"\u003e\nTitanium\n\u003c\/li\u003e\n\u003cli data-section-id=\"xqg3pu\" data-start=\"1826\" data-end=\"1836\"\u003e\nTantalum\n\u003c\/li\u003e\n\u003cli data-section-id=\"ooj2qj\" data-start=\"1839\" data-end=\"1875\"\u003e\nPlatinum-Iridium (model dependent)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ov2jjs\" data-start=\"1876\" data-end=\"1917\"\u003e\nAmbient Temperature:\n\u003cul data-start=\"1901\" data-end=\"1917\"\u003e\n\u003cli data-section-id=\"1yl5wa9\" data-start=\"1901\" data-end=\"1917\"\u003e\n-20°C to +60°C\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"krwqh2\" data-start=\"1918\" data-end=\"2019\"\u003e\nFluid Temperature:\n\u003cul data-start=\"1941\" data-end=\"2019\"\u003e\n\u003cli data-section-id=\"1s6xns5\" data-start=\"1941\" data-end=\"2019\"\u003e\nUp to 130°C depending on configuration \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1212f2c\" data-start=\"2021\" data-end=\"2033\"\u003eFunction\u003c\/h3\u003e\n\u003cp data-start=\"2034\" data-end=\"2429\"\u003eThe ABB COPA-XE measures liquid flow using Faraday's Law of Electromagnetic Induction. As conductive fluid passes through the magnetic field generated within the flow tube, a voltage proportional to flow velocity is induced and measured by the transmitter. This allows highly accurate flow measurement without mechanical wear or obstruction within the pipe. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"ucz99x\" data-start=\"2431\" data-end=\"2455\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2456\" data-end=\"2755\"\u003e\n\u003cli data-section-id=\"v859ql\" data-start=\"2456\" data-end=\"2480\"\u003e\nWater treatment plants\n\u003c\/li\u003e\n\u003cli data-section-id=\"105lvlu\" data-start=\"2481\" data-end=\"2504\"\u003e\nWastewater processing\n\u003c\/li\u003e\n\u003cli data-section-id=\"lmsru4\" data-start=\"2505\" data-end=\"2529\"\u003e\nChemical manufacturing\n\u003c\/li\u003e\n\u003cli data-section-id=\"11eqzuy\" data-start=\"2530\" data-end=\"2558\"\u003e\nFood \u0026amp; beverage production\n\u003c\/li\u003e\n\u003cli data-section-id=\"p9ze3o\" data-start=\"2559\" data-end=\"2586\"\u003e\nPharmaceutical processing\n\u003c\/li\u003e\n\u003cli data-section-id=\"ted9g3\" data-start=\"2587\" data-end=\"2619\"\u003e\nMining and slurry applications\n\u003c\/li\u003e\n\u003cli data-section-id=\"d6phxs\" data-start=\"2620\" data-end=\"2647\"\u003e\nPulp and paper industries\n\u003c\/li\u003e\n\u003cli data-section-id=\"35jcse\" data-start=\"2648\" data-end=\"2677\"\u003e\nUtility and process systems\n\u003c\/li\u003e\n\u003cli data-section-id=\"1k22h21\" data-start=\"2678\" data-end=\"2755\"\u003e\nIndustrial liquid transfer monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003eWe have a wide range of industrial items such as pressure transmitters, temperature transmitters, flow meters, and loads more!\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Contact Number: 07915071899\u003c\/div\u003e\n\u003cdiv\u003eMSTAK Email: mdalrymple@stakam.co.uk\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e⸻\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eFull Specifications:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e• Manufacturer: ABB\u003c\/div\u003e\n\u003cdiv\u003e• Model: COPA-XE\u003c\/div\u003e\n\u003cdiv\u003e• Enclosure Rating: IP67\u003c\/div\u003e\n\u003cdiv\u003e• Serial Number: 00119496\/X002\u003c\/div\u003e\n\u003cdiv\u003e• Flanges: 2 x 3\" flanges\u003c\/div\u003e\n\u003cdiv\u003e• Hazardous Area Certification: \u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003eEx TUV 97 ATEX 1173 X II 2G EEx emd [ib] IIC T3 bis T6\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1108\" style=\"border-collapse:\n collapse;width:831pt\"\u003e\u003c\/table\u003e• ATEX Certified\u003c\/div\u003e\n\u003cdiv\u003e• IECEx Approved\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e⸻\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e✔ Used in great condition\u003c\/div\u003e\n\u003cdiv\u003e✔ Stored correctly in dry environment\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Meter Type:\u003c\/strong\u003e Electromagnetic Flow Meter\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e COPA-XE\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53860579410248,"sku":"FG004","price":570.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0971\/6383\/7768\/files\/57_334b3ca3-997e-4ea7-8233-fcb00b8dd6c9.png?v=1787159789","url":"https:\/\/www.mstak.co.uk\/products\/abb-copa-xe-electromagnetic-flowmeter-1","provider":"MSTAK","version":"1.0","type":"link"}